Ultraviolet disinfection method
Time:25.04.2021Reading times:645

The ultraviolet disinfection method can be divided into direct irradiation method and indirect irradiation method. The precautions in using ultraviolet lamp disinfection include the cleaning of ultraviolet disinfection lamp, the environment of ultraviolet disinfection and the case protection measures of ultraviolet disinfection.
Methods of ultraviolet disinfection:
1. disinfection of the surface of the article: portable ultraviolet sterilizer can be used to move the irradiation at close range, or ultraviolet lamp suspension close range irradiation. Small items can be placed in the ultraviolet disinfection box irradiation disinfection.
2. disinfection of indoor air:
Indirect irradiation method: the first choice is high intensity ultraviolet air sterilizer, not only the disinfection effect is reliable, but also can be used when someone is active in the room.
Direct irradiation: under the condition of no one in the room, ultraviolet lamp suspension or mobile direct irradiation can be adopted. During indoor suspended ultraviolet disinfection, the number of indoor ultraviolet disinfection lamps installed is not less than 1.5 per cubic meter W, and the irradiation time is not less than 30 minutes.

II. Matters needing attention in ultraviolet disinfection
1. lamp surface should be regularly (every 2 weeks) with 75% alcohol cotton ball wipe, remove the dust and grease above it, to reduce the impact on ultraviolet penetration.
2. the ultraviolet ray is invisible to the naked eye, the blue light emitted by the lamp tube does not represent the ultraviolet intensity. The radiation illuminance value of the lamp tube should be detected regularly, and the ultraviolet radiometer or the special indicator card for measuring the ultraviolet intensity within the validity period can be used to determine whether the ultraviolet lamp has reached the service life. All irradiation intensity below 70 uW/cm2 should be replaced in time.
During 3. disinfection, the room should be kept clean and dry to reduce dust and water mist in the air.
The suitable temperature range of 4. ultraviolet disinfection is 20-40℃. If the temperature is too high or too low, it will affect the disinfection effect, prolong the disinfection time properly, and prolong the irradiation time when the relative humidity is more than 80.
5. only the side directly exposed to ultraviolet radiation can achieve the purpose of disinfection.
6. can not look directly at the ultraviolet light source. Under ultraviolet light work should strengthen personal protection, wear protective glasses.
7. when purchasing ultraviolet disinfection lamp, the supplier shall be required to provide the relevant manufacturer's hygiene license and product qualification certificate. The service life of ultraviolet disinfection lamp is generally not more than 600 hours. If the lamp tube is unstable after opening or the lamp diode becomes black, it should be replaced in time. It is recommended to use ultraviolet illuminometer for daily monitoring to ensure the effectiveness of ultraviolet lamp disinfection.

PREV: Factors affecting ultraviolet sterilization
NEXT:Sterilization characteristics and precautions of ultraviolet lamp